---
格式版本: 2
标题: "On-chip Bragg peak extraction from MHz frame rate X-ray detectors using a cellular automaton architecture"
原文链接: "https://arxiv.org/abs/2608.18970"
发布日期: "2026-08-19"
发布时间校准状态: "found"
发布时间需复核: "否"
发布时间来源: "rule:local:strict_original_body"
发布时间证据: "**\\[v1\\]** Wed, 19 Aug 2026 14:39:18 UTC (2,569 KB)"
发布时间校准原因: "规则确认唯一严格发布时间，来源 local:strict_original_body"
发布时间校准置信度: "high"
发布时间候选数量: 18
发布时间严格候选数量: 6
发布时间原页读取状态: "source template page reused from URL open"
发布时间未找到原因: ""
发布时间校准时间: "2026-08-20T14:35:11+08:00"
发布时间仲裁状态: "skipped"
发布时间仲裁尝试次数: 0
发布时间仲裁耗时毫秒: 0
发现时间: "2026-08-20T14:32:56+08:00"
入库时间: "2026-08-20T06:35:11.409Z"
来源平台: "arXiv 学术论文搜索"
搜索渠道: "source_template"
搜索词: "https://arxiv.org/search/?query=AMD&searchtype=all"
匹配关键词:
  - "bandwidth"
  - "throughput"
相关厂家:
  - "AMD"
相关专家:
  []
内容类型: "网页"
抓取工具: "Free Fetch + Defuddle"
清洗工具: "Defuddle Markdown + Defuddle/Readability 正文提取"
原始附件:
  []
AI优质: "否"
AI打分: 5
AI分档: "非优质"
AI质检状态: "不通过"
AI打分理由: "论文主题为X射线探测器峰值提取硬件架构，与超节点/AI Rack/机柜级AI基础设施无关，仅提及AMD FPGA作为验证平台，不构成相关技术信号。"
AI质检模型: "ali-deepseek-v4-flash"
AI质检时间: "2026-08-20T14:35:55+08:00"
AI主题相关性: 0
AI来源权威性: 5
AI新颖性: 0
AI技术细节: 0
AI商业部署信号: 0
AI完整性: 0
AI摘要: "研究人员提出一种在X射线探测器硅片内直接提取布拉格峰的轻量级硬件架构，用固定迭代的元胞自动机替代传统连通分量标记，只传输小图像块而非整帧，避免片外带宽瓶颈。"
AI摘要模型: "ali-deepseek-v4-flash"
AI摘要时间: "2026-09-07T03:18:17.973Z"
采集批次: "2026年8月20日14点19分32秒"
采集批次ID: "20260820-141932-079"
去重键: "https://arxiv.org/abs/2608.18970"
---

## Physics > Instrumentation and Detectors

## Title:On-chip Bragg peak extraction from MHz frame rate X-ray detectors using a cellular automaton architecture

Authors:[S. Fowler](https://arxiv.org/search/physics?searchtype=author&query=Fowler,+S), [S. Strempfer](https://arxiv.org/search/physics?searchtype=author&query=Strempfer,+S), [D. Beniwal](https://arxiv.org/search/physics?searchtype=author&query=Beniwal,+D), [M. Hammer](https://arxiv.org/search/physics?searchtype=author&query=Hammer,+M), [H. Shi](https://arxiv.org/search/physics?searchtype=author&query=Shi,+H), [S. Gnanasekaran](https://arxiv.org/search/physics?searchtype=author&query=Gnanasekaran,+S), [N. Contini](https://arxiv.org/search/physics?searchtype=author&query=Contini,+N), [T. Guruswamy](https://arxiv.org/search/physics?searchtype=author&query=Guruswamy,+T), [Y. Chen](https://arxiv.org/search/physics?searchtype=author&query=Chen,+Y), [L. Rota](https://arxiv.org/search/physics?searchtype=author&query=Rota,+L), [D. Doering](https://arxiv.org/search/physics?searchtype=author&query=Doering,+D), [A. Dragone](https://arxiv.org/search/physics?searchtype=author&query=Dragone,+A), [T. Zhou](https://arxiv.org/search/physics?searchtype=author&query=Zhou,+T), [M. Cherukara](https://arxiv.org/search/physics?searchtype=author&query=Cherukara,+M), [K. Yoshii](https://arxiv.org/search/physics?searchtype=author&query=Yoshii,+K), [A. Miceli](https://arxiv.org/search/physics?searchtype=author&query=Miceli,+A)

[View PDF](https://arxiv.org/pdf/2608.18970) [HTML (experimental)](https://arxiv.org/html/2608.18970v1)

> Abstract:High-frame rate pixel detectors can produce data volumes that exceed available off-chip bandwidth, yet in many applications only a sparse subset of each frame carries relevant information. Spatially localized events, including diffraction peaks in crystallography, particle hits in tracking detectors, fluorescence spots in biological imaging, and other applications, all require that clusters of above-threshold pixels be identified and extracted from an otherwise featureless background. Conventionally this is performed in software algorithms such as connected-component labeling on full frames, but at MHz frame rates the resulting throughput becomes prohibitive. We present a lightweight hardware architecture that performs peak localization and patch extraction directly in the sensor silicon, transmitting only small pixel patches rather than complete frames. FPGA-based testing on an AMD Alveo V80 validated the synthesizability and timing closure of the peak-finding module in real hardware. The design replaces global connected-component labeling with a cellular automaton that uses purely local, fixed-iteration neighborhood operations, eliminating the label storage and equivalence-resolution logic that make conventional approaches impractical on-chip. We validate the architecture on X-ray Bragg peak detection for far-field high-energy diffraction microscopy and show that every peak found by a software reference is recovered, with equivalent downstream reconstructions. The architecture sustains several-hundred-kHz frame rates in 130nm CMOS and exceeds 1MHz in 28nm.

| Comments: |  |
| --- | --- |
| Subjects: | Instrumentation and Detectors (physics.ins-det) |
| Cite as: | [arXiv:2608.18970](https://arxiv.org/abs/2608.18970) \[physics.ins-det\] |
|  | (or [arXiv:2608.18970v1](https://arxiv.org/abs/2608.18970v1) \[physics.ins-det\] for this version) |
|  | [https://doi.org/10.48550/arXiv.2608.18970](https://doi.org/10.48550/arXiv.2608.18970) |

## Submission history

From: Samantha Fowler \[[view email](https://arxiv.org/show-email/206dd386/2608.18970)\]  
**\[v1\]** Wed, 19 Aug 2026 14:39:18 UTC (2,569 KB)

[Which authors of this paper are endorsers?](https://arxiv.org/auth/show-endorsers/2608.18970) | Disable MathJax ([What is MathJax?](https://info.arxiv.org/help/mathjax.html))
