格式版本: 2
标题: "A NICE (Nulling Interferometry Cryogenic Experiment) update: Beyond 1e-5 and towards cryogenic operation"
原文链接: "https://arxiv.org/abs/2608.16297"
发布日期: "2026-08-17"
发布时间校准状态: "found"
发布时间需复核: "否"
发布时间来源: "rule:local:strict_original_body"
发布时间证据: "**\\[v1\\]** Mon, 17 Aug 2026 09:10:45 UTC (4,412 KB)"
发布时间校准原因: "规则确认唯一严格发布时间，来源 local:strict_original_body"
发布时间校准置信度: "high"
发布时间候选数量: 18
发布时间严格候选数量: 6
发布时间原页读取状态: "source template page reused from URL open"
发布时间未找到原因: ""
发布时间校准时间: "2026-08-20T15:48:14+08:00"
发布时间仲裁状态: "skipped"
发布时间仲裁尝试次数: 0
发布时间仲裁耗时毫秒: 0
发现时间: "2026-08-20T15:43:02+08:00"
入库时间: "2026-08-20T07:48:14.859Z"
来源平台: "arXiv 学术论文搜索"
搜索渠道: "source_template"
搜索词: "https://arxiv.org/search/?query=throughput&searchtype=all"
匹配关键词:
  - "throughput"
  - "performance"
相关厂家:
  []
相关专家:
  []
内容类型: "网页"
抓取工具: "Free Fetch + Defuddle"
清洗工具: "Defuddle Markdown + Defuddle/Readability 正文提取"
原始附件:
  []
AI优质: "否"
AI打分: 5
AI分档: "非优质"
AI质检状态: "不通过"
AI打分理由: "该资料为arXiv天体物理论文，涉及零差干涉低温实验，与超节点、AI Rack、机柜级AI基础设施完全无关。"
AI质检模型: "ali-deepseek-v4-flash"
AI质检时间: "2026-08-20T15:55:05+08:00"
AI主题相关性: 0
AI来源权威性: 5
AI新颖性: 0
AI技术细节: 0
AI商业部署信号: 0
AI完整性: 0
AI摘要: "ETH Zürich的NICE中红外测试台在环境温度前驱实验中实现了单波长重复低于1e-5的零值和高吞吐，并进一步研究了宽波段与双偏振下的零值表现；团队正为LIFE任务所需的低温运行安装15K低温恒温器，以验证材料与光机装调方案。"
AI摘要模型: "ali-deepseek-v4-flash"
AI摘要时间: "2026-09-07T03:25:52.970Z"
采集批次: "2026年8月20日14点19分32秒"
采集批次ID: "20260820-141932-079"
去重键: "https://arxiv.org/abs/2608.16297"
---

## Astrophysics > Instrumentation and Methods for Astrophysics

## Title:A NICE (Nulling Interferometry Cryogenic Experiment) update: Beyond 1e-5 and towards cryogenic operation

[View PDF](https://arxiv.org/pdf/2608.16297) [HTML (experimental)](https://arxiv.org/html/2608.16297v1)

> Abstract:The Nulling Interferometry Cryogenic Experiment (NICE) is a mid-infrared laboratory testbed at ETH Zürich that aims to not only reproduce the deep ($<1\times10^{-5}$) broadband nulls of the nulling testbeds of the early 2000s, but also at the required sensitivity levels expected for the LIFE space mission. This sensitivity enforces the experiment to go cryogenic at temperatures around 15 K; an ambitious task for an ultra-precise interferometer. We share our results of the ambient precursor experiment, demonstrating repeatable $<1\times10^{-5}$ nulls at a single wavelength and high throughput, and investigations into the nulling performance across a broader bandpass and with dual polarisation states. We will also highlight the push towards cryogenic operation, with the instalment of a new 15 K test cryostat that will inform our choices of materials and optomechanical mounting techniques.

| Comments: |  |
| --- | --- |
| Subjects: | Instrumentation and Methods for Astrophysics (astro-ph.IM) |
| Cite as: | [arXiv:2608.16297](https://arxiv.org/abs/2608.16297) \[astro-ph.IM\] |
|  | (or [arXiv:2608.16297v1](https://arxiv.org/abs/2608.16297v1) \[astro-ph.IM\] for this version) |
|  | [https://doi.org/10.48550/arXiv.2608.16297](https://doi.org/10.48550/arXiv.2608.16297) |

## Submission history

From: Jonah Hansen \[[view email](https://arxiv.org/show-email/7b5da695/2608.16297)\]  
**\[v1\]** Mon, 17 Aug 2026 09:10:45 UTC (4,412 KB)

[Which authors of this paper are endorsers?](https://arxiv.org/auth/show-endorsers/2608.16297) | Disable MathJax ([What is MathJax?](https://info.arxiv.org/help/mathjax.html))