格式版本: 2
标题: "From Safety Documentation to Safety Knowledge Support: An Evidence-Grounded LLM Framework for Medical Devices"
原文链接: "https://arxiv.org/abs/2608.12025"
发布日期: "2026-08-12"
发布时间校准状态: "found"
发布时间需复核: "否"
发布时间来源: "rule:local:strict_original_body"
发布时间证据: "**\\[v1\\]** Wed, 12 Aug 2026 13:05:49 UTC (127 KB)"
发布时间校准原因: "规则确认唯一严格发布时间，来源 local:strict_original_body"
发布时间校准置信度: "high"
发布时间候选数量: 18
发布时间严格候选数量: 6
发布时间原页读取状态: "source template page reused from URL open"
发布时间未找到原因: ""
发布时间校准时间: "2026-08-13T18:33:45+08:00"
发布时间仲裁状态: "skipped"
发布时间仲裁尝试次数: 0
发布时间仲裁耗时毫秒: 0
发现时间: "2026-08-13T18:24:32+08:00"
入库时间: "2026-08-13T10:33:45.288Z"
来源平台: "arXiv 学术论文搜索"
搜索渠道: "source_template"
搜索词: "https://arxiv.org/search/?query=AI&searchtype=all"
匹配关键词:
  - "AI"
相关厂家:
  []
相关专家:
  []
内容类型: "网页"
抓取工具: "Free Fetch + Defuddle"
清洗工具: "Defuddle Markdown + Defuddle/Readability 正文提取"
原始附件:
  []
AI质检状态: "评分失败"
AI评分尝试次数: 1
AI评分错误类型: "service_error"
AI评分错误: "LLM call failed; tried model chain: ali-deepseek-v4-flash -> tx-deepseek-v4-flash | Model ali-deepseek-v4-flash failed 500: {\"error\":{\"code\":\"\",\"message\":\"Database error, please contact the administrator (request id: 202608131033469425527318268d9d6rGTwptts)\",\"type\":\"new_api_error\"}} | Model tx-deepseek-v4-flash failed 500: {\"error\":{\"code\":\"\",\"message\":\"Database error, please contact the administrator (request id: 202608131033482294464698268d9d66qfcJUDi)\",\"type\":\"new_api_error\"}}"
AI评分开始时间: "2026-08-13T10:33:45.294Z"
AI评分结束时间: "2026-08-13T10:33:48.341Z"
AI摘要: "该文提出一个基于证据的LLM框架，将医疗设备工件、知识存储检索、候选安全条目生成、批判性检查与专家评审相连接，用于支持ISO 14971和IEC 62304相关的安全文档一致性维护。"
AI摘要模型: "ali-deepseek-v4-flash"
AI摘要时间: "2026-09-07T03:40:18.667Z"
采集批次: "2026年8月13日18点24分27秒"
采集批次ID: "20260813-182427-1564e572"
去重键: "https://arxiv.org/abs/2608.12025"
---

## Computer Science > Software Engineering

## Title:From Safety Documentation to Safety Knowledge Support: An Evidence-Grounded LLM Framework for Medical Devices

[View PDF](https://arxiv.org/pdf/2608.12025) [HTML (experimental)](https://arxiv.org/html/2608.12025v1)

> Abstract:Medical devices are becoming more software-intensive, connected, and AI-enabled. Their development requires risk-management evidence aligned with ISO 14971 and, for software, IEC 62304. This evidence must be kept consistent across requirements, design decisions, software changes, verification results, complaints, and post-market data. These tasks are costly and depend on scarce safety and domain experts.  
> Large language models (LLMs) may reduce parts of this effort because medical-device safety work is highly document-based. However, current LLM-based safety-engineering studies often address isolated methods, rely on generic prompting or public examples, and provide limited support for source links, traceability, uncertainty handling, lifecycle updates, and recorded expert review. This limits their use in regulated medical-device development.  
> This paper argues that the central research problem is not safety-text generation, but source-linked safety-knowledge support. We propose an evidence-grounded framework that connects device artifacts, controlled knowledge storage and retrieval, method-specific generation of candidate safety items, critique and uncertainty checks, and recorded expert review. The framework prepares, links, checks, and updates candidate safety artifacts for expert decision-making. It does not decide whether a device is safe and does not provide regulatory approval. We also outline an evaluation strategy using non-public or newly built medical-device case studies and expert reference analyses to assess coverage, correctness, relevance, traceability, duplicate rate, unsupported claims, and review effort.

| Comments: |  |
| --- | --- |
| Subjects: | Software Engineering (cs.SE); Artificial Intelligence (cs.AI) |
| Cite as: | [arXiv:2608.12025](https://arxiv.org/abs/2608.12025) \[cs.SE\] |
|  | (or [arXiv:2608.12025v1](https://arxiv.org/abs/2608.12025v1) \[cs.SE\] for this version) |
|  | [https://doi.org/10.48550/arXiv.2608.12025](https://doi.org/10.48550/arXiv.2608.12025) |

## Submission history

From: Rasmus Adler \[[view email](https://arxiv.org/show-email/57263093/2608.12025)\]  
**\[v1\]** Wed, 12 Aug 2026 13:05:49 UTC (127 KB)

[Which authors of this paper are endorsers?](https://arxiv.org/auth/show-endorsers/2608.12025) | Disable MathJax ([What is MathJax?](https://info.arxiv.org/help/mathjax.html))